NTI FTVN Series
The FTVN is a high efficiency, wall hung boiler using a durable, vertical down-fired stainless heat exchanger. With 10:1 modulation and 96% AFU, an integrated ECM pump and DHW diverter, quick connect components, WIFI connectivity for remote monitoring and alert notifications, the FTVN is an ideal solution for your ‘peace of mind’, home heating needs.
Click to View the NTI FTVN Brochure
NTI FTVN Specifications
MODEL | FTVN085 | FTVN110 | FTVN150 | FTVN199 | FTVN110C | FTVN150C | FTVN199C |
---|---|---|---|---|---|---|---|
Space Heating Minimum / Maximum Input (Btu/Hr) |
8,500 / 85,000 | 11,000 / 110,000 |
15,000 / 150,000 |
19,900 / 199,000 | 11,000 / 110,000 |
15,000 / 150,000 |
19,900 / 199,000 |
Domestic Hot Water Capacity (77F Rise) in GPM |
N/A | N/A | N/A | N/A | 2.7 | 3.6 | 4.8 |
DOE AFUE (%) | 96 | 95 | 95 | 95 | 95 | 95 | 95 |
Heating Capacity | 79 | 101 | 138 | 184 | 101 | 138 | 184 |
Net AHRI Rating | 69 | 88 | 120 | 160 | 88 | 120 | 160 |
Installation type | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing | Indoor, Wall Hung, Fully Condensing |
Weight (lbs.) | 107 | 107 | 122 | 139.5 | 107 | 128.5 | 140.5 |
Gas Connection | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT |
CH Connections | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT | 1 1/4” Male NPT |
DHW Connections | N/A | N/A | N/A | N/A | 3/4” Male NPT | 3/4” Male NPT | 3/4” Male NPT |
Flue | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent | Category IV, Sealed Combustion Direct Vent, Power Vent |
Minimum – Maximum Exhaust Vent Run | 2” (6 – 100 feet), 3” (6 – 150 feet) | 2” (6 – 100 feet), 3” (6 – 150 feet) | 2” (6 – 100 feet), 3” (6 – 150 feet) | 3” (6 – 150 feet) | 2” (6 – 100 feet), 3” (6 – 150 feet) | 2” (6 – 100 feet), 3” (6 – 150 feet) | 3” (6 – 150 feet) |
Minimum – Maximum Intake Air Pipe Run | 2” (0 – 100 feet), 3” (0 – 150 feet) | 2” (0 – 100 feet), 3” (0 – 150 feet) | 2” (0 – 100 feet), 3” (0 – 150 feet) | 3” (0 – 150 feet) | 2” (0 – 100 feet), 3” (0 – 150 feet) | 2” (0 – 100 feet), 3” (0 – 150 feet) | 3” (0 – 150 feet) |
Power Supply | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A | 120V, 60 Hz, less than 12A |